Bijur Delimon Electric V5W Pump– LUB V5 ASSY 115V 200 PSI CV:
Startup Instructions:
- Ensure the reservoir is filled with oil.
- Activate the machine and check that oil is being distributed to all bearings.
Maintenance: Regularly check the oil level each day and refill the reservoir as necessary. Periodically inspect the system for any loose or damaged tubing, hoses, fittings, and connections. It’s recommended to replace the filter group once a year.
Filter Replacement: The system is protected by an inlet filter, which should be inspected every six months and replaced if found to be unclean.
Motor Replacement: Cut off the power supply to the motor, disconnect the system’s tubing, and remove the lubricator unit from the oil reservoir.
Invert the lubricator unit and unscrew the hex of the filter inlet connector rod/filter from the pump in a counter-clockwise direction to remove it, along with the inlet gear pump adapter and O-ring.
Detach the two M4 SHC screws that secure the gear pump to the downspout and remove the gear pump. Then, remove the three #8-32 socket cap screws that attach the downspout to the motor and lift the downspout away from the motor.
Install the new motor and carefully reattach the motor driveshaft/motor coupling to the new motor shaft, ensuring the motor coupling is evenly positioned between the motor driveshaft and the motor shaft.
Reattach the downspout to the motor, aligning the three holes and securing them with the three #8-32 socket cap screws.
Reconnect the gear pump to the downspout, making sure the gear pump’s shaft aligns with the motor driveshaft. Attach the inlet gear pump adapter and O-ring to the gear pump, and secure them with the two M4 SHC screws.
Reinsert the filter inlet connector rod/filter into the gear pump adapter.